EUTECTIC CORP -- EUTECTOR 157 FLUX ======================================================= MSDS Safety Information ======================================================= FSC: 3439 MSDS Date: 01/27/1994 MSDS Num: BYHRT LIIN: 00F008246 Product ID: EUTECTOR 157 FLUX MFN: 02 Responsible Party Cage: 72271 Name: EUTECTIC CORP Address: 9625-J SOUTHERN PINE BOULEVARD City: CHARLOTTE NC 28273 Info Phone Number: 718-358-4000 Emergency Phone Number: 718-358-4000 Review Ind: Y Published: Y ======================================================= Preparer Co. when other than Responsible Party Co. ======================================================= Cage: 72271 Name: EUTECTIC CORP Address: 9600-H SOUTHERN PINE BLVD City: CHARLOTTE NC 28217 ======================================================= Contractor Summary ======================================================= Cage: 72271 Name: EUTECTIC CORP Address: 9600-H SOUTHERN PINE BLVD City: CHARLOTTE NC 28217 Phone: 800-323-4845 ======================================================= Ingredients ======================================================= Cas: 7646-85-7 RTECS #: ZH1400000 Name: ZINC CHLORIDE % Wt: >50 OSHA PEL: 1 MG/CUM ACGIH TLV: 1 MG/CUM EPA Rpt Qty: 1000 LBS DOT Rpt Qty: 1000 LBS ------------------------------ Cas: 12125-02-9 RTECS #: BP4550000 Name: AMMONIUM CHLORIDE OSHA PEL: 10 MG/CUM ACGIH TLV: 10 MG/CUM EPA Rpt Qty: 5000 LBS DOT Rpt Qty: 5000 LBS ------------------------------ Cas: 7681-49-4 RTECS #: WB0350000 Name: SODIUM FLUORIDE OSHA PEL: 2.5 MG/CUM ACGIH TLV: 2.5 MG/CUM EPA Rpt Qty: 1000 LBS DOT Rpt Qty: 1000 LBS ------------------------------ Cas: 7732-18-5 RTECS #: ZC0110000 Name: WATER ======================================================= Health Hazards Data ======================================================= Route Of Entry Inds - Inhalation: YES Skin: NO Ingestion: YES Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO Effects of Exposure: INHALATION: OVEREXPOSURE MAY CAUSE LUNG &/OTHER ORGAN DAMAGE. INGESTION: MAY BE HARMFUL/FATAL. EYES/SKIN: ARC RAYS & ULTRAVIOLET LIGHT CAN INJURE EYES & BURN SKIN. LIQUIDS MAY CAUSE IRRITATION/POSSIBLE CHEMICAL BURNS. ELECTRICAL SHOCK CAN K ILL. Explanation Of Carcinogenicity: PER EUTECTIC CORP, ZINC CHLORIDE IS A NTP, IARC & OSHA CARCINOGEN. Signs And Symptions Of Overexposure: IRRITATION, BURNS, DIZZINESS, NAUSEA, DRYNESS, BRONCHIAL ASTHMA. METAL FUME FEVER-CHILLS, FEVER, HEAD & MUSCLE ACHE, TIGHTNESS OF CHEST, DRYNESS OF NOSE & MOUTH, MUSCULAR PAIN, NAUSEA, VOMITING. Medical Cond Aggravated By Exposure: PRE-EXISTING RESPIRATORY/ALLERGIC CONDITIONS. First Aid: INHALATION: REMOVE TO FRESH AIR. SKIN: THOROUGHLY WASH AFFECTED AREAS W/SOAP & WATER TO REMOVE ALL RESIDUE. EYES: THOROUGHLY FLUSH W/WATER FOR 15 MINS TO REMOVE ALL RESIDUE. OBTAIN MEDICAL ATTENTION IN ALL CASES. ======================================================= Handling and Disposal ======================================================= Spill Release Procedures: USE APPROPRIATE MEASURES TO KEEP AIRBORNE DUST LEVELS CONTAINED IAW EXPOSURE LEVELS. Waste Disposal Methods: DISPOSE OF WASTE MATERIAL, POWDERS, GRINDING/FILTER RESIDUES IN AN ENVIRONMENTALLY SENSITIVE MANNER IAW/FEDERAL, STATE & LOCAL REGULATIONS. Handling And Storage Precautions: WEAR APPROPRIATE EQUIPMENT TO PREVENT INJURY FROM RADIATION, SPARKS & ELECTRICAL SHOCK. USE W/ADEQUATE VENTILATION. Other Precautions: TRAIN WORKERS NOT TO TOUCH LIVE ELECTRICAL PARTS & TOINSULATE THEMSELVES FROM WORK & ELECTRICAL GROUND. TRAIN WELDER TO KEEPHIS/HER FACE AWAY FROM FUME/DUST PLUME. MONITOR THE AIR TO ENSURE THELEVELS ARE <THE RECOMMENDED LIMITS. ======================================================= Fire and Explosion Hazard Information ======================================================= Flash Point Text: NONFLAMMABLE Extinguishing Media: CO2, DRY CHEMICAL FOAM TYPE. Fire Fighting Procedures: WEAR AN APPROVED SELF-CONTAINED BREATHING APPARATUS. Unusual Fire/Explosion Hazard: CANS, UNDER PRESSURE, & FLAMMABLES MAY EXPLODE. SOME FLUXES & CHEMICAL AIDS MAY GIVE OFF HYDROGEN CHLORIDE, PHOSGENE & CHLORINE GAS. ======================================================= Control Measures ======================================================= Respiratory Protection: WEAR A NIOSH APPROVED RESPIRATOR IF WORK STATION ISN'T PROPERLY VENTILATED TO EXHAUST ALL FUMES, VAPORS & DUSTS <RECOMMENDED EXPOSURE LIMITS. Ventilation: GENERAL/LOCAL EXHAUST AT WORK SITE TO KEEP FUMES & DUST FROM WORKER'S BREATHING ZONE & GENERAL AREA. Protective Gloves: WELDERS Eye Protection: HELMET, FACE SHIELD W/FILTER LENS Other Protective Equipment: ARM PROTECTORS, APRONS, HATS & DARK PROTECTIVE CLOTHING Supplemental Safety and Health: COMPOSITION & QUANTITY OF FUMES/GASES/DUSTS DEPENDS ON METAL BEING WELDED, PROCESS, PROCEDURES, ELECTRODES USED, COATINGS, POSITION OF WORKER'S HEAD W/RESPECT TO FUMES GENERATED, PRESENCE OF CONTAMINANTS IN ATMOSPHERE, NUMBER OF WORKERS & V OLUME OF WORK SPACE, QUALITY & AMOUNT OF VENTILATION. ======================================================= Physical/Chemical Properties ======================================================= Appearance and Odor: FLUX (LIQUID, AMBER). ======================================================= Reactivity Data ======================================================= Stability Indicator: YES Stability Condition To Avoid: SUPP Materials To Avoid: SUPP Hazardous Decomposition Products: METAL OXIDES, FLUORIDE COMPOUNDS, CARBON, SILICA, OZONE, CO, CO2, NITROGEN OXIDES. (SEE SUPP) Hazardous Polymerization Indicator: NO ======================================================= Toxicological Information ======================================================= ======================================================= Ecological Information ======================================================= ======================================================= MSDS Transport Information ======================================================= ======================================================= Regulatory Information ======================================================= ======================================================= Other Information ======================================================= ======================================================= HAZCOM Label ======================================================= Product ID: EUTECTOR 157 FLUX Cage: 72271 Company Name: EUTECTIC CORP Street: 9600-H SOUTHERN PINE BLVD City: CHARLOTTE NC Zipcode: 28217 Health Emergency Phone: 718-358-4000 Label Required IND: Y Date Of Label Review: 12/16/1998 Status Code: C Label Date: 12/16/1998 Origination Code: G Hazard And Precautions: INHALATION: OVEREXPOSURE MAY CAUSE LUNG &/OTHER ORGAN DAMAGE. INGESTION: MAY BE HARMFUL/FATAL. EYES/SKIN: ARC RAYS & ULTRAVIOLET LIGHT CAN INJURE EYES & BURN SKIN. LIQUIDS MAY CAUSE IRRITATION/POSSIBLE CHEMICAL BURNS. ELECTRICAL SHOCK CAN K ILL. IRRITATION, BURNS, DIZZINESS, NAUSEA, DRYNESS, BRONCHIAL ASTHMA. METAL FUME FEVER-CHILLS, FEVER, HEAD & MUSCLE ACHE, TIGHTNESS OF CHEST, DRYNESS OF NOSE & MOUTH , MUSCULAR PAIN, NAUSEA, VOMITING. ======================================================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever expressly or implied warrants, states, or intends said information to have any application, use or viability by or to any person or persons outside the Department of Defense nor any person or persons contracting with any instrumentality of the United States of America and disclaims all liability for such use. Any person utilizing this instruction who is not a military or civilian employee of the United States of America should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation regardless of similarity to a corresponding Department of Defense or other government situation.